Microtest OMNIScanner LT Especificaciones Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 153
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
102
OMNISCANNER
6.3.2 TDNXT E
XAMPLES
The following examples show the diagnostics process that is performed to identify
failures on typical links with 2 meter test cables.
GOOD CABLE, BAD CONNECTION:
The cursor in the NEXT graph is located at the worst NEXT at 144.0 MHz, which is
outside the limit line. (For an easier interpretation the cursor was moved.) The
Link failed. Why?
Press to open the TDNXT screen to further review and diagnose the
graph.
The cursor is positioned at the worst peak, which is outside the S-Bands.
Looking at the TDNXT graph we can reach the conclusion that the connection
located at 2 meters did not meet the required performance and is the cause of
failure.
Vista de pagina 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 152 153

Comentarios a estos manuales

Sin comentarios