Press to open the TDRL screen to further review and diagnose the
graph.
The cursor is positioned at the worst peak, which is outside the S-Bands.
Looking at the TDRL graph we can reach the conclusion that the connection
located at 2 meters did not meet the required performance and is the cause of
failure.
BAD CABLE, GOOD CONNECTION:
The cursor in the Return Loss graph is located at the worst Return Loss at 110.4
MHz, which is outside the limit line. The Link failed. Why?
CHAPTER 6: Diagnostics